. IV Fluid / Blood Warming System Operator’s Manual Vital Signs a GE Healthcare Company. © 2012 General Electric Company – All rights reserved. All specifications subject to change without notice. GE, GE Monogram, and Vital Signs are trademarks of General Electric Company. enFlow is a trademark of General Electric Company Enginivity, LLC., a subsidiary of Vital Signs, Inc. Symbols Used on the Equipment The following symbols may be viewed on the any of the products or accessories that comprise the enFlow IV Fluid/Blood Warming System.
Symbol Symbol Description Symbol Symbol Description Batch Code Catalog Number Serial Number Not made with natural rubber latex National Stock No. System Fault XX Low Battery Lock or Password required Unlock The CE Mark is the manufacturer’s or importer’s mark of Do not throw in trash conformity declaring compliance with all applicable directives (Safety, EMC, Machinery, Medical and others). Interek is accredited by OSHA as a NRTL, as well as by the Standards Council of Canada.
CAUTIONS. 7 UNPACKING THE ENFLOW IV FLUID/BLOOD WARMING SYSTEM.9 TO BEGIN OPERATION OF THE ENFLOW IV FLUID/BLOOD WARMING SYSTEM. 9 ENFLOW CONTROLLER (MODEL 120 SERIES) INDICATORS AND OPERATION.
11 ENFLOW WARMER (MODEL 100 SERIES) INDICATORS AND OPERATION. 13 CLEANING THE ENFLOW IV FLUID/BLOOD WARMING SYSTEM COMPONENTS. IV Fluid/Blood Warming System Description The enFlow IV Fluid/Blood Warming System consists of the enFlow Warmer (Model 100 series), the enFlow Controller (Model 120 series), the enFlow Disposable Cartridge with or without IV Extension Set (Model 200 series). Within seconds, this Warming System delivers normothermic infusate to the patient at flow rates of Keep Vein Open (KVO) to 200 mL/min when input fluid temperature is 20 °C. WARNINGS All IV fluid bags must be vented of air per IV fluid manufacturers’ directions prior to connecting to the infusion set. Standard IV line protocols for priming the complete infusion set, the enFlow Disposable Cartridge, and the extension set must be followed before connecting to a patient. Do not block the fan in the Controller as this may cause overheating.
Although the Warmer has been tested to insure it will survive a drop of 1 m (3.28 ft.), care should be taken that the device is not dropped to reduce the potential of damage. Setting the clock to the local time is optional, but usually done on initial use. No changes in performance are affected by the clock’s setting. D) Connect the enFlow IV Fluid/Blood Warmer cable to the Controller. This action is accomplished in three steps: 1.
Turn right to lock. (See arrows on label.) e) The rear mounted I/0 (ON/OFF) switch on the Controller turns the power on and off. Switch the Controller to ON.
Upon startup, the Controller conducts a self-test. The power indicator illuminates green, the Controller display flashes “enFlow”, a short audible “Beep”. k) Do not wrap the Warmer in towels, sheets, blankets or drapes. Opening the Warmer covers immediately stops the heating but not the flow.
M) To turn off the device, use the switch located at the rear of the controller. EnFlow Controller (Model 120 series) Indicators and Operation Keypad Controller Display. Controller Display The Controller display continuously reflects the specific infusate temperature that the Warmer monitors and maintains.
The various readouts that may be depicted on the Controller display are described in the following tabulation: Table 1: Controller Display: Normal Operating Model Activity Display Reads Display Color and. enFlow Warmer (Model 100 series) Indicators and Operation The Warmer monitors and maintains the infusate temperature at 40 °C ± 2 °C. On the top of the Warmer, there are two status indicator lights (multicolored LEDs), which reflect the following: Power - indicates the power and operational status of the Warmer. Table 4: Indicator Status Status Warmer Disposable Power Temperature Audible Description Action Required Covers Cartridge Indicator Indicator Indicator Ready Open or None Flashing Unlit None Warmer unit has None Closed Green power, but is not every 3 heating seconds Power up Closed In place Red ½. Refer to Appendix C for the chart on “Warming System Response versus Fluid Temperature”.
Refer to Warnings for additional information. Cleaning the enFlow IV Fluid/Blood Warming System Components Caution Do not clean with: ketones (MEK, acetone, etc.) or . Controller.
If fluid ingress is detected, set the Controller aside for an extended period of time to allow it to dry. Storing the enFlow IV Fluid/Blood Warming System Components The Warmer and Controller should be stored in a clean, dust free environment.
(See Appendix A) 4400-0024 enFlow Operator’s Manual EN Rev. IV Fluid/Blood Warming System Operational Checklist Warmer Serial No Controller Serial No Warming System Location/Identifier Date: Procedure Instructions Pass Input Output Fail Temp Temp Inspection Ensure that all cords and connectors are in good condition and void of any cuts, cracks, or frays. The systems use current Surface Mount Technology (SMT) and materials.
If service is required, it must be performed by Vital Signs – a GE Healthcare Company or one of its authorized agents. Service by others voids the warranty and transfers the liability for malfunctions of the device to the servicer.
Appendix A: Technical Specifications Warmer: 12.7 cm L x 6.6 cm W x 3.0 cm H, (5.0 in. Size W x 1.2 in. H) Controller: 23.6 cm L x 16.8 cm W x 9.7 cm H, (9.3 in. Continuous Note Electromagnetic Compatibility (EMC) The enFlow IV Fluid / Blood Warmer System has been tested and found to comply with the limits for medical devices as set forth in IEC 60601-1-2: (2001) and related standards. These limits are designed to provide reasonable protection against electromagnetic interference (EMI) in a typical medical installation. Guidance and Manufacturer’s Declaration - Emissions The enFlow 100 with enFlow 120 is intended for use in the electromagnetic environment specified below.
The customer or user of the enFlow 100 with enFlow 120 should ensure that it is used in such an environment. Emissions Test Compliance Electromagnetic Environment –. D=(3.5/3V/m)(Sqrt P) 80 to 800 MHz D=(7/3V/m)(Sqrt P) 800 MHz to 2.5 GHz where P is the max power in watts and D is the recommended separation distance in meters. Field strengths from fixed transmitters, as determined by an electromagnetic site survey, should be less than the compliance levels (3Vrms and 3V/m). Rain- Operational 1. Place an enFlow Power Supply /Controller in the rain chamber. Connect the enFlow IV Fluid Warmer and the extended power cable to the power supply.
Turn “on” the power supply. Expose to 1” of rain per minute in its left IV pole orientation for 10 minutes.
Appendix B: Glossary enFlow IV Fluid/Blood The enFlow IV Fluid/Blood Warming System consists of three products: Warming System the Warmer (No. 980100), the Controller (No. 980121), and the Disposable Cartridge (No. 980200), which together form a system designed to warm intravenous fluids and blood products helping reduce hypothermic effects. Appendix C: Warming System Response by Temperature Fluid Heater Temperature LED on Display on Controller Audible Temp Warmer Alarm 30 °C Active Blue Flashing 30°C Blue Flashing 31 °C Active Blue Flashing 31°C Blue Flashing 32 °C Active Blue Flashing 32°C Blue Flashing 33 °C Active. Appendix D: Parts List 980105VS Warmer 980121EU Controller 980200EU Disposable cartridge 980202EU Disposable cartridge with IV extension set 980305VS Warmer Holder 980309VS Warmer Cord Clip 980307 enCheck Alarm testing Tool 44000024 Operator’s manual (USA) 44000060 Service manual (electronic version only, not available in print) 44000120 enCheck Users Guide English(EN) 91000178.
DESCRIPTION The right temperature, in the right place, at the right time. When it comes to fluid warming, there is a system that can help you maintain normothermia with accuracy, mobility and speed. The enFlow. system from GE Healthcare delivers the right temperature in the right place at the right time.
EnFlow can help providers deliver higher quality care to more people—part of GE’s healthymagination commitment. EnFlow can help maintain normothermia across your patient population with accuracy, mobility and speed.
The Right Temperature By consistently helping to maintain the right patient temperature, enFlow brings the opportunity for both clinical and economic benefits to your hospital. Maintaining normothermia can help lessen complications and speed up recovery time – all while reducing length of stay and hospital costs. The Right Place True system mobility and a small transferable cartridge allow enFlow to help maintain normothermia in the right place- throughout all care areas. It can be used before, during and after procedures, and because its cartridge is easily transported from room to room, enFlow maintains your workflow while saving steps.
The Right Time The enFlow system enables warmed infusate delivery at the right time across all clinical areas—right away, and within seconds. Its low priming volume reduces the time needed to reach temperature set point thus allowing the warming process to start quickly, while its close proximity to the patient reduces heat loss across the IV line. CalDave 7 months ago 7 months ago Does anyone have the service manual for these that you can send me? Dave FEATURES Accuracy. The system warms fluids automatically to 40 ± 2°C and has redundant sensors to ensure fluid temperature accuracy. The lightweight warmer (9.5 oz) can be placed close to the patient – allowing less opportunity for fluid-cooling in the IV line. It has a low priming volume (4mL), which reduces waste and improves control over fluid composition.
The warmer incorporates a layer that transfers heat effectively and prevents hot spots Mobility. When it’s time to move, the cartridge and the IV set are removed from the warming unit only to be reinserted into a warmer in the next area. The warming unit and power source are highly durable and have been shock and vibration tested. The cartridge may stay in-line to protect the IV set from potential infection – whether fluid is being warmed or not. The enFlow cartridge can be used for 24 hours of continuous patient warming. Speed. It warms fluids rapidly (18 s or less) to a temperature of 40 °C, so there’s no time spent waiting to warm (other warmers can take over 10 min).
The cartridge attaches in-line to standard IV sets at the start of procedures, so there’s no additional set-up or tubing requirements. It offers one-button operation. It's intuitive and relatively easy to operate, simply turn on the power and be warming within seconds. It requires little preventive maintenance (five year schedule) and no calibrations. SPECIFICATIONS Height 1.2 in Length 5 in Weight 9.7 oz Width 2.5 yd Additional Specifications Fluid Temperature Output: 40 °C ± 2 °C Flow Rate Range: KVO to 200 mL/min.